The AA-7000 Series of Atomic Absorption Spectrophotometers offers high precision analysis, flexible system configuration and a compact footprint for user-friendly operation. In addition, Shimadzu AA-7000 systems are the first AAs to use a vibration sensor as standard. The AA-7000 series provides efficient and comfortable working in your laboratory.
Dual Beam optics and stable hardware provide superior stability. The AA-7000 Atomic Absorption Spectrometer series includes newly developed 3D dual-beam optics. The optical system has been designed to produce its maximum performance for each measurement method, using optimal adjustment of the light beam and light beam digital filter and optical components that limit light losses.
Advances in optics and a new graphite furnace design achieve improved lower limits of Enhanced Sensitivity due to Graphite Furnace detection for furnace analysis. This superb analysis performance is possible in all fields.
Atomic Absorbtion Spectrophotometer AA-7000F/AAC creates an integral burner and furnace that remains permanently installed in the combustion chamber. It supports both flame analysis of high concentration samples and furnace analysis of trace samples, without changing the atomizer unit. The integral construction with the atomizer saves space.
AA-7000F enables above function by AAC-7000 (option).
Safety is an extremely important consideration for flame atomic absorption spectrophotometers using acetylene gas. The AA-7000 AAS Spectrometer Series instruments are the first* ones in the world fitted with a vibration sensor as standard. They also incorporate a comprehensive range of safety mechanisms, including gas leak detectors.
Seawater, river water, effluent, sludge, air-borne dust
Metals, minerals, glass, ceramics, IC chips
Petroleum, oil, catalysts, chemical products, biodiesel
Blood, animals, plants, drugs, food products
This procedure describes the method of atomization with hydride (cold steam) to be used to determine the amount of mercury in Atomic Absorption (AA) in whole blood samples.
Instrument: Shimadzu AA-7000 Atomik Absorpsiyon Spektrofotometre
This procedure describes the electrothermal atomic absorption method (GFA) to be used to determine the amount of chromium in Atomic Absorption AA in whole blood and urine samples.
Instrument: Shimadzu AA-7000 Atomik Absorpsiyon Spektrofotometre
This procedure describes the electrothermal atomic absorption method to be used to determine the amount of selenium in AA in complete serum samples.
Instrument: Shimadzu AA-7000
This procedure describes the method of electrothermal atomic absorption to be used to determine the amount of nickel in AA in whole blood and urine samples.
Instrument: Shimadzu AA-7000