Adrona

B300 Ultra Pure Water Device

The Adrona B300 system is an ultrapure water purification system that requires an external water tank (tap water system) that uses tap water as feed water. It is available in 3 different configurations: B300 Trace, B300 HPLC, B300 Bio. B300 model is a laboratory water system that produces Type1/Type2 water with its new integrated design, replacing the previous B30 model. The B300 model features a completely new electronic system and software, providing several additional features: a large color touch screen, data logging capability, warning and alarm messages, a wide range of flow control options, the ability to connect to multiple external dispensers, Ethernet and USB interfaces, dispensing report preparation, and enhanced accuracy for conductivity and TOC measurements.
 

Key Features;

  • Extensive flow control options
  • Dispense report preparation
  • Improved measurement accuracy
  • Convenient 7-inch colour touch screen
  • Data logging option
  • Ethernet & USB interfaces

Technical Information:
B300 Application Trace HPLC Bio
Reagent Preparation
Flame AAS
Autoclaves
ICP-MS
ICP-OES
İon Chromatography
Liquid Chromatography (HPLC)  
Gas Chromatography (GC)  
TOC Measurements  
Flow Cytometry    
Cell and Tissue Culture    
Molecular Biology    
 
 

Feed Water Requirements for Pure Water System;

·       Feed Water: Potable Tap Water

·       Pressure: 0,4 – 6,0 bar

·       Conductivity: <2000 μS/cm

·       Temperature: 5–35 °C

If the feed water does not meet specifications, additional pre-treatment solutions are available.

 
B300 Technical Specifications Trace HPLC Bio
Grade 1 Water Resistivity at 25°C 18.2 MΩ x cm 18.2 MΩ x cm 18.2 MΩ x cm
Grade 1 Water Conductivity at25°C 0.055 μS/cm 0.055 μS/cm 0.055 μS/cm
Grade 2 Water Resistivity at 25°C >10 MΩ x cm >10 MΩ x cm >10 MΩ x cm
Grade 2 Water Conductivity at 25°C < 0.1 μS/cm < 0.1 μS/cm < 0.1 μS/cm
TOC Level < 10 ppb < 5 ppb* < 5 ppb*
Rnase - - < 0.01 ng/mL
Dnase - - < 4 pg/mL
Bacteria < 0.01 CFU/mL < 0.01 CFU/mL < 0.01 CFU/mL
Endotoxins < 0.15 EU/mL < 0.15 EU/mL < 0.001 EU/mL
Particles >0.22 μm < 1/mL < 1/mL < 0,05/mL
Nominal flow, Pure Water (to storage tank) 10 L/h 10 L/h 10 L/h
Dispense rate, ultrapure water 1,5-2L/min 1,5-2L/min 1,5-2L/min
Dimensions (WxDxH), cm 32*56*58 cm 32*56*58 cm 32*56*58 cm
System Weight, kg 27 28 29
Operating Weight, kg 30 31 32
                                               * In appropriate operating conditions <2 ppb, otherwise normally <5 ppb.


Consumables Required for B300;
 
Part No. Description Explanation
10319 Pre-filter set  
10311 Deionization Q w/ quick connectors  
10031 Polishing Q w/ quick connectors  
10033 Polishing QC w/ quick connectors  
10037 Polishing QH w/ quick connectors  
10017 Sterilization UV bulb For Bio configuration
10018 UV photooxidation bulb  
10013 0.22 µm dispense microfilter, sterile For HPLC configuration
10120 Ultrafilter For Bio configuration
410175 UV bulb For automatic sanitization module