B310 Ultra Pure Water Device

The Adrona B310 water system is an enhanced addition to the B300 model, designed to produce all types of water for laboratory applications: Grade 1, Grade 2, and Reverse Osmosis water. The Adrona B300 system is an ultra-pure water purification system that requires an external water tank (tap water system) as its feed water source. There are two different configurations available: B310 HPLC and B310 Bio. The B310 model features a completely new electronic system and software, providing several additional features: a large color touch screen, data logging capability, warning and alarm messages, a wide range of flow control options, the ability to connect to multiple external dispensers, Ethernet and USB interfaces, dispensing report preparation, and enhanced accuracy for conductivity and TOC measurements.


 

Key Features;

  • Grade 1, Grade 2 and RO water preparation
  • Data logging option
  • Ethernet & USB interfaces
  • Dispense report preparation
  • 7-inch colour touch screen
  • Improved measurement accuracy
  • Extensive flow control options
  • A pressurised tank can be added for RO water storage

Technical Information:
B310 Application HPLC Bio
Reagent Preparation
Laboratory Type Washing Equipment
Flame AAS
Autoclaves
ICP-MS
ICP-OES
İon Chromatography
Liquid Chromatography (HPLC)
Gas Chromatography (GC)
TOC Measurements
Flow Cytometry  
Cell and Tissue Culture  
Molecular Biology  
 

Feed Water Requirements for Pure Water System;

·       Feed Water: Potable Tap Water

·       Pressure: 0,4 – 6,0 bar

·       Conductivity: <2000 μS/cm

·       Temperature: 5–35 °C

If the feed water does not meet specifications, additional pre-treatment solutions are available.

 
B310 Technical Specifications HPLC Bio
Grade 1 Water Resistivity at 25°C 18.2 MΩ x cm 18.2 MΩ x cm
Grade 1 Water Conductivity at25°C 0.055 μS/cm 0.055 μS/cm
Grade 2 Water Resistivity at 25°C >10 MΩ x cm >10 MΩ x cm
Grade 2 Water Conductivity at 25°C < 0.1 μS/cm < 0.1 μS/cm
TDS rejection rate ≥97% ≥97%
TOC Level < 5 ppb* < 5 ppb*
Rnase - < 0.01 ng/mL
Dnase - < 4 pg/mL
Bacteria < 0.01 CFU/mL < 0.01 CFU/mL
Endotoxins < 0.15 EU/mL < 0.001 EU/mL
Particles >0.22 μm < 1/mL < 0,05/mL
Nominal flow, Pure Water (to storage tank) 10 L/h 10 L/h
Dispense rate, ultrapure water 1,5-2L/min 1,5-2L/min
Dimensions (WxDxH), cm 32*56*58 cm 32*56*58 cm
System Weight, kg 28 29
Operating Weight, kg 31 32
 
                                                          * In appropriate operating conditions <2 ppb, otherwise normally <5 ppb.
 

Consumables Required for B310;
Part No. Description Explanation
10319 Pre-filter set  
10311 Deionization Q w/ quick connectors  
10031 Polishing Q w/ quick connectors  
10033 Polishing QC w/ quick connectors  
10037 Polishing QH w/ quick connectors  
10017 Sterilization UV bulb For Bio configuration
10018 UV photooxidation bulb  
10013 0.22 µm dispense microfilter, sterile For HPLC configuration
10120 Ultrafilter For Bio configuration
410175 UV bulb For automatic sanitization module