Shimadzu Corporation

GC-2010 Plus Gas Chromatography System (front-end GCMS)

GC-2010 Plus Gas Chromatography System represents a new generation in top end capillary GC analysis, redefining sensitivity limits for trace analysis, fast GC applications, and easy, robust operation.
Advanced Flow Technology (AFT) capability further extends the applications scope of the instrument allowing multidimensional GC, capillary backflush, and other specialized flow applications. AFT additionally enables reduced analysis times, enhanced chromatographic resolution, and application-specific configurations without comprising key performance features. The new detector line-up, featuring sensitivity specifications among the highest (i.e. FID: 1.5 pgC/s (Dodacane)) in the industry, ensures quality data across a broad range of applications
 

  • Column Oven Temperature : (Room temperature + 4°C) to 450°C
  • Carrier Gas Control : Digital setting by electronic flow controller, Advanced Flow Controller
  • Detector Gas Control : Digital setting by electronic pressure controller, Advanced Pressure Controller
  • Sample Injector : Split/Splitless, Direct, On- column/Programmable Temperature Vaporizer Injection
  • Detectors : FID, BID, TCD, ECD, FPD, FTD (NPD), MS.
  • Optional, 12 vial or 150 vial capacitied liquid auto sampler
  • Optional automatic Head Space, SPME, Purge and Trap, Thermal Desorber and Pyrolisis Unit

 

GC-2010 Plus represents a new generation in top end capillary GC analysis, redefining sensitivity limits for trace analysis, fast GC applications, and easy, robust operation. Advanced Flow Technology (AFT) capability further extends the applications scope of the instrument allowing multidimensional GC, capillary backflush, and other specialized flow applications. AFT additionally enables reduced analysis times, enhanced chromatographic resolution, and application-specific configurations without comprising key performance features. The new detector line-up, featuring sensitivity specifications among the highest (i.e. FID: 1.5 pgC/s (Dodacane)) in the industry, ensures quality data across a broad range of applications

  • Column Oven Temperature : (Room temperature + 4°C) to 450°C
  • Carrier Gas Control : Digital setting by electronic flow controller, Advanced Flow Controller
  • Detector Gas Control : Digital setting by electronic pressure controller, Advanced Pressure Controller
  • Sample Injector : Split/Splitless, Direct, On- column/Programmable Temperature Vaporizer Injection
  • Detectors : FID, BID, TCD, ECD, FPD, FTD (NPD), MS.
  • Optional, 12 vial or 150 vial capacitied liquid auto sampler
  • Optional automatic Head Space, SPME, Purge and Trap, Thermal Desorber and Pyrolisis Unit

  • VOC (Volatile Organic Carbon) Determination in GC-FID Flue Gas

    In this study, the application of volatile organic carbon (VOC) determination in flue gas by means of Gas Chromatography (GC) system is included.
     
    Instrument: Shimadzu GC-2010 Plus Gas Chromatograph
     

  • Sterol Analysis of Vegetable Oils by GC-FID

    Determination of sterol in vegetable oils

    Instrument: Shimadzu GC-2010 Plus Gas Chromatograph

  • Determination of Fatty Acid Methyl Esters in Vegetable Oils by GC-FID

    Vegetable oils were converted to methyl ester derivatives and analyzed.

    Instrument: Shimadzu GC-2010 Plus Gas Chromatograph

  • Analysis of Human Blood Alcohol using GC-HS-FID

    Particularly in judicial cases, the amount of alcohol and foreign substances in the human blood should be calculated as promil. The purpose of this study is to analyze the blood alcohol level using a gas chromatograph and headspace method.


    Instrument: Shimadzu GC-2010 Plus Gas Chromatograph with Headspace Unit (GC-HS)