Teknokroma

Teknokroma GC Columns

As Ant Teknik, we offer a wide range of products to meet the analytical needs for all GC, GCxGC, GCMS and GCMSMS applications.

GC column series of Teknokroma company has capillary columns of different sizes and special applications.

Some examples

  • Drug analysis
  • VOC analysis in water, VOC analysis with Purge and Trap
  • Pesticide analysis
  • Fatty acid methyl esters analysis
  • Acidic substance analysis, etc.

Teknokroma TRB-1MS

100% dimethylpolysiloxane filler material, USP phase G2, non-polar column, ultra low column bleeding and GC / MS compatibility, different film thicknesses and lengths.
100% dimethylpolysiloxane, TRB-1MS column, USP G2, non-polar, GCMS 1 column, low bleeding

Teknokroma TRB-5MS

5% diphenyl-95% dimethylpolysiloxane filler material, USP phase G27, weak polar column, ultra low column bleeding and GC / MS compatibility, different film thicknesses and lengths.
5% diphenyl-95% dimethylpolysiloxane, TRB-5MS column, USP G27, weak polar, GCMS 5 column, low bleeding

Teknokroma Meta.X5

Polysiloxane loaded silfenylene filler, USP phase G27, weak polar column, ultra low column bleeding and GC / MS compatibility, different film thicknesses and lengths.
Silfenylene filler material, Meta.X5 column, USP G27, weak polar, low bleeding

Teknokroma Meta.XLB

Low polar column, selective column to aromatic compounds (PCBs, PAHs, PBDEs) of different film thickness and length.
XLB column, PACBs, PAHs, PBDEs, low polar, Meta.XLB, aromatic selector

Teknokroma Sapiens-1MS

100% dimethylpolysiloxane filler material, USP phase G2, non-polar column, ultra low column bleeding and GC / MS compatibility, different film thicknesses and lengths.
100% dimethylpolysiloxane, Sapiens-1MS column, USP G2, non-polar, GCMS 1 column, low bleeding

Teknokroma Sapiens-5MS

5% diphenyl-95% dimethylpolysiloxane filler material, USP phase G27, weak polar column, ultra low column bleeding and GC / MS compliance, high chemical inertness, different film thicknesses and lengths.
5% diphenyl-95% dimethylpolysiloxane, Sapiens-5MS column, USP G27, weak polar, high inert, low bleeding

Teknokroma Sapiens-X5ms

Polysiloxane-loaded silfenylene filler, USP phase G27, weak polar column, ultra low column bleeding and GC / MS compatibility, thermal stability and high inertia, different film thicknesses and lengths.
Silfenylene filler material, Sapiens-X5ms column, USP G27, weak polar, low bleeding, thermal stability

Teknokroma Sapiens-Wax.ms

100% Polyethyleneglycol filling material, strong polar column, USP phase G16 G14 G15 G20 G39, for the analysis of polar materials, different film thickness and length.
100% polyethyleneglycol, USP G16 G14 G15 G20 G39, high polar, polar substance analysis, Sapiens-Wax

Teknokroma TRB-Sterol

95% dimethyl-5% diphenylpolysiloxane filler, developed specifically for sterol analysis, with different film thicknesses and lengths.
95% dimethyl-5% diphenylpolysiloxane, sterol analysis, TRB-Sterol

Teknokroma TR-CN100

100% Bissyanopropyl polysiloxane filler material, USP phase G48, high polar column, high selectivity in FAME cis-trans isomers, fatty acid analysis, different film thicknesses and lengths.
100 Bissyanopropyl polysiloxane, USP G48, FAME analysis, cis trans analysis
 

Recommend Me a System

Please Recommend Me a Column