Thermo Fisher Scientific

Thermo Scientific™ KingFisher™ Duo Prime Purification System

Obtain high yields of quality nucleic acids from a variety of starting materials with the Thermo Scientific™ KingFisher™ Duo Prime Purification System. This compact device is ideal for laboratories requiring nucleic acid purification and can be easily modified for use in proteomics and cell isolation. It provides excellent repeatability with minimal application time and has a small footprint in the laboratory. New features such as UV lamp for easy decontamination and optional barcode reader increase functionality.

The Thermo Scientific KingFisher Duo Prime is the most versatile compact desktop sample preparation in the lab for 6 or 12 samples per run. It provides consistent extraction and purification of DNA, RNA, proteins and cells and includes an ultraviolet lamp for decontamination. KingFisher Duo Prime is an affordable choice for academic or small labs.

Move beads, not liquids, for purity and sample integrity

Many automated liquid handling systems and purfication instruments move reagents into and out of wells to perform the different steps of nucleic acid isolation. In contrast, Thermo Scientifc KingFisher Sample Purification Systems use permanent magnetic rods with disposable tip combs to collect beads from solution, then release them into successive wells, each containing reagents for the next step of isolation. This highly effective method of bead collection and transfer leads to clean extractions, efficient results, and preservation of sample. Using a simple process (bind, wash, elute), KingFisher instruments can automate the extraction of any analyte of interest that can be bound to a bead, even from challenging samples.

move-beads-diagram













 

Moving beads instead of liquids results in higher purity because no non-target organic matter or contaminants from liquid reagents are transferred from well to well. It also minimizes sample loss and results in higher yield since you can optimize your protocol so that no beads, with their target nucleic acids attached, are left behind in solution.

Manual sample preparation and sample loss can introduce inconsistencies into samples, which show up in your data as outliers and wider error bars. High-end downstream applications such as qPCR, NGS, digital PCR, and mass spectrometry can be very sensitive to these inconsistencies. KingFisher instruments reduce user processing errors while increasing the reproducibility of your results. Our data show that samples processed with KingFisher instruments have consistent results across different runs and different users.

More speed, less touch

KingFisher instruments help save you valuable time by removing manual steps and reducing overall processing time when compared with manual preparation or even with other sample preparation instruments. This not only improves workflow efficiency but also reduces exposure to potentially infectious samples.

With KingFisher automation, each step in your workflow—such as reagent, antibody, target capture, washes, and elution—is represented by a single plate in the instrument carousel (or, for the KingFisher Duo Prime, rows of wells in the plate). Once the plates are prepared and loaded, simply press Start and the instrument carries out the programmed protocol automatically. As each step is completed, the carousel rotates to bring the next plate underneath the magnetic head and tip combs.


gdna-blood-graph















 



A KingFisher Flex system can isolate viral RNA from a 96-well plate in only 25 minutes. A typical lab using 1–4 Flex instruments can easily process 1,000–4,000 samples in an 8-hour day. Using highly automated KingFisher Presto instruments can process the same number of samples but with far less attention from laboratory staff. 

word

 
KingFisher Instrument
Duo Prime

Flex

Apex

Presto
Instrument size Compact benchtop Benchtop Benchtop

Benchtop—integrates with robotic liquid handler

Throughput level Low to medium Medium to high Medium to high Ultrahigh
Processing volume range  50-1,000 μL: 12-pin magnet head
200-5,000 μL: 6-pin magnet head

 

20-100 μL: 96-well PCR plate, skirted*
20-200 μL: 96-well plate
50-1,000 μL: 96 deep-well plate
200-5,000 μL: 24 deep-well plate

 

15-1,000 μL: 96 deep-well plate
15-200 μL: 96-well KingFisher standard plate
10-80 μL: 96-well PCR plate
30-5,000 μL: 24 deep-well plate
30-200 μL: 96 storage tubes
200-1,000 μL: 24 storage tubes

 

50-1,000 μL: 96 deep-well plate
200-5,000 μL; 24 deep-well plate
50-150 μL: 96-well KingFisher standard plate

 

Samples per run 6-12 24-96 24-96 24-96
Customizable protocols Yes, with PC software Yes, with PC software Yes, with touchscreen or PC software Yes, with PC software
Heating/cooling 10°C to 75°C (plate row block A)
4°C to 75°C (elution strip block)

 

From 5°C above ambient temperature to 115°C

 

From 4°C above ambient temperature to 100°C
Cooling down to 4°C

 

From 5°C above ambient temperature to 115°C

 

Ultraviolet lamp 8 watts (up to 16 hr) No 2 UV lamps, max 23 h 59 min No
Size 40 x 46 x 34 cm; 15.7 x 18.1 x 13.4 in. (W x D x H) 68 x 60 x 38 cm; 26.77 x 23.6 x 14.96 in. (W x D x H) 78 x 59 x 45 cm; 31 x 23 x 18 in. (W x D x H) 36 x 46.5 x 40 cm; 14.2 x 18.3 x 15.7 in. (W x D x H)
Weight 17 kg; 37.5 lbs. 28 kg; 62 lbs. 56 kg; 123 lbs. 24 kg; 52.9 lbs.
Ordering information KingFisher Duo Prime Purification System 5400110

 

KingFisher Flex Purification System with 96 PCR Head 5400610 
KingFisher Flex Purification System with 96 
KingFisher Head 5400620 
KingFisher Flex Purification System with 24 Deep-Well Head 5400640 
KingFisher Flex Purification System with 96 Deep-Well Head 5400630
  KingFisher Presto Purification System with 24 Deep-Well Head. 5400840 
KingFisher Presto Purification System with 96 Deep-Well Head. 5400830

 

Applications

KingFisher systems can gently and efficiently isolate and purify nucleic acids, proteins, and cells from a range of sample types for a wide variety of downstream applications.

kingfisher-systems-chart

Different chemistries handle a multitude of sample types. KingFisher systems offer the flexibility to process even difficult samples such as blood, saliva, mucus, seawater, soil, fecal matter, fish scales, and other sample types. KingFisher systems can handle sample preparation for an extraordinary range of applications.

Different sample types and applications require different chemistries to extract the analyte. To simplify selection and ease of use, we’ve developed kits and solutions that contain optimized beads, buffers, and protocols to maximize purity and yield for each application and sample type. The Kits, Reagents, and Protocols section contains details about these applications and kits, but here are a few highlights:

MagMAX kits for optimized nucleic acid extraction. For automated extraction of DNA and RNA using KingFisher systems, the reagents of choice are Applied Biosystems MagMAX kits. For example, MagMAX Viral/Pathogen Nucleic Acid Isolation Kits can be used to extract and purify RNA from swabs or other samples types. Other popular MagMAX kits help you extract genomic DNA (gDNA) from a variety of samples; circulating cell-free DNA for liquid biopsies; DNA and RNA from formalin-fixed, paraffin embedded (FFPE) samples for clinical cancer research; and total RNA and miRNA for gene expression research.

Dynabeads and SMART Digest reagents for other targets. KingFisher instruments can use Invitrogen Dynabeads magnetic beads or Thermo Scientific SMART Digest kits to capture and isolate other nucleic acids, proteins, and cell structures. For example, you could use a SMART Digest kit to automate protein digestion of a monoclonal antibody like ipilimumab or rituximab (Rituxan®) for in-depth peptide mapping and characterization. You can pair a KingFisher instrument with Dynabeads magnetic beads to capture CD9+ tumor-derived exosomes for downstream analysis with flow cytometry or western blot.

All kits and many reagents include modifiable protocols optimized for KingFisher instruments. To find kits and reagents for your application, browse the Kits, Reagents, and Protocols tab or use our Selection Guide. If you need assistance customizing reagents or developing protocols for your particular application needs, our Field Application Specialists and Technical Sales Specialists will be happy to help.

Complete, optimized Dynabeads-based system

KingFisher sample preparation instruments are optimized for use with MagMAX nucleic acid purification kits, Dynabeads reagents, and KingFisher plates and plastics. These products are designed and manufactured to exacting standards and the protocols developed for them have been tested, refined, and validated. When you use these products and protocols together, you can have confidence in the performance of your instrument and the purity, yield, and sample integrity of your results.

a room with a bed and a table

Optimization for Dynabeads magnetic bead reagents (which are also included in MagMAX purification kits) is central to consistent binding and reliable results. Dynabeads are superparamagnetic particles, meaning that they exhibit magnetic properties when placed in a magnetic field, with no residual magnetism once removed from the field. They are gentle on cells and molecules, capturing targets directly from biological samples in tubes or plates, without columns or centrifugation.
Dynabeads magnetic beads have a defined surface to carry out the necessary binding, with no inner surface to trap unwanted proteins. 
A. Dynabeads products are the most uniform, monodispersed superparamagnetic beads, manufactured with highly controlled product quality
to help ensure the highest degree of reproducibility. B,C,D. Magnetic particles from alternative suppliers have variable shapes and sizes that
trap impurities, resulting in lower reproducibility and increased nonspecific binding.


Downloadable, customizable protocols

To help ensure that KingFisher systems can adapt to your changing research needs, Thermo Scientific BindIt BindIx software is included free with all KingFisher instruments.

The software lets you create, modify, and store your own protocols on your PC, transfer them to your KingFisher instrument, and track their execution on the instrument screen during the course of your run. It also allows you to define and edit steps and parameters for every part of your protocol—bind, wash, and elute—as well as define KingFisher plates and reagents in the plate layout. If you have already developed a manual protocol, you can convert to an automated protocol in minutes!

Protocols are available for MagMAX and Dynabeads nucleic acid isolation kits, as well as Dynabeads and SMART Digest protein purification products. Once loaded onto your instrument, you can modify the protocols and store them for future reuse.

streamline-protocols-chart1

Specifications

Instrument size Compact benchtop
Throughput level Low to medium
Processing volume range 50–1,000 µL: 12-pin magnet head
200–5,000 µL: 6-pin magnet head
Sample per run 6-12
Software Bindit
Customizable protocols Yes (with BindIt software)
Heating/cooling 10ºC–75ºC (plate row block A)
4ºC–75ºC (elution strip block)
Ultraviolet lamp 8 watts (up to 16 hr)
Bar code reader With BindIt software or standalone
Use-selectable magnetic heads 2
Standalone use Yes
Size 40 x 46 x 34 cm; 15.7 x 18.1 x 13.4 in. (W x D x H)
Weight 17 kg; 37.5 Ibs

For more information please click.

Recommend Me a System

Please Recommend Me a Column