Moving beads instead of liquids results in higher purity because no non-target organic matter or contaminants from liquid reagents are transferred from well to well. It also minimizes sample loss and results in higher yield since you can optimize your protocol so that no beads, with their target nucleic acids attached, are left behind in solution.
Manual sample preparation and sample loss can introduce inconsistencies into samples, which show up in your data as outliers and wider error bars. High-end downstream applications such as qPCR, NGS, digital PCR, and mass spectrometry can be very sensitive to these inconsistencies. KingFisher instruments reduce user processing errors while increasing the reproducibility of your results. Our data show that samples processed with KingFisher instruments have consistent results across different runs and different users.
KingFisher instruments help save you valuable time by removing manual steps and reducing overall processing time when compared with manual preparation or even with other sample preparation instruments. This not only improves workflow efficiency but also reduces exposure to potentially infectious samples.
With KingFisher automation, each step in your workflow—such as reagent, antibody, target capture, washes, and elution—is represented by a single plate in the instrument carousel (or, for the KingFisher Duo Prime, rows of wells in the plate). Once the plates are prepared and loaded, simply press Start and the instrument carries out the programmed protocol automatically. As each step is completed, the carousel rotates to bring the next plate underneath the magnetic head and tip combs.
A KingFisher Flex system can isolate viral RNA from a 96-well plate in only 25 minutes. A typical lab using 1–4 Flex instruments can easily process 1,000–4,000 samples in an 8-hour day. Using highly automated KingFisher Presto instruments can process the same number of samples but with far less attention from laboratory staff.
KingFisher Instrument | Duo Prime |
Flex |
Apex |
Presto |
Instrument size | Compact benchtop | Benchtop | Benchtop |
Benchtop—integrates with robotic liquid handler |
Throughput level | Low to medium | Medium to high | Medium to high | Ultrahigh |
Processing volume range | 50-1,000 μL: 12-pin magnet head 200-5,000 μL: 6-pin magnet head
|
20-100 μL: 96-well PCR plate, skirted* 20-200 μL: 96-well plate 50-1,000 μL: 96 deep-well plate 200-5,000 μL: 24 deep-well plate
|
15-1,000 μL: 96 deep-well plate 15-200 μL: 96-well KingFisher standard plate 10-80 μL: 96-well PCR plate 30-5,000 μL: 24 deep-well plate 30-200 μL: 96 storage tubes 200-1,000 μL: 24 storage tubes
|
50-1,000 μL: 96 deep-well plate 200-5,000 μL; 24 deep-well plate 50-150 μL: 96-well KingFisher standard plate
|
Samples per run | 6-12 | 24-96 | 24-96 | 24-96 |
Customizable protocols | Yes, with PC software | Yes, with PC software | Yes, with touchscreen or PC software | Yes, with PC software |
Heating/cooling | 10°C to 75°C (plate row block A) 4°C to 75°C (elution strip block)
|
From 5°C above ambient temperature to 115°C
|
From 4°C above ambient temperature to 100°C Cooling down to 4°C
|
From 5°C above ambient temperature to 115°C
|
Ultraviolet lamp | 8 watts (up to 16 hr) | No | 2 UV lamps, max 23 h 59 min | No |
Size | 40 x 46 x 34 cm; 15.7 x 18.1 x 13.4 in. (W x D x H) | 68 x 60 x 38 cm; 26.77 x 23.6 x 14.96 in. (W x D x H) | 78 x 59 x 45 cm; 31 x 23 x 18 in. (W x D x H) | 36 x 46.5 x 40 cm; 14.2 x 18.3 x 15.7 in. (W x D x H) |
Weight | 17 kg; 37.5 lbs. | 28 kg; 62 lbs. | 56 kg; 123 lbs. | 24 kg; 52.9 lbs. |
Ordering information | KingFisher Duo Prime Purification System 5400110
|
KingFisher Flex Purification System with 96 PCR Head 5400610 KingFisher Flex Purification System with 96 KingFisher Head 5400620 KingFisher Flex Purification System with 24 Deep-Well Head 5400640 KingFisher Flex Purification System with 96 Deep-Well Head 5400630 |
KingFisher Presto Purification System with 24 Deep-Well Head. 5400840 KingFisher Presto Purification System with 96 Deep-Well Head. 5400830
|
Different chemistries handle a multitude of sample types. KingFisher systems offer the flexibility to process even difficult samples such as blood, saliva, mucus, seawater, soil, fecal matter, fish scales, and other sample types. KingFisher systems can handle sample preparation for an extraordinary range of applications.
Different sample types and applications require different chemistries to extract the analyte. To simplify selection and ease of use, we’ve developed kits and solutions that contain optimized beads, buffers, and protocols to maximize purity and yield for each application and sample type. The Kits, Reagents, and Protocols section contains details about these applications and kits, but here are a few highlights:
MagMAX kits for optimized nucleic acid extraction. For automated extraction of DNA and RNA using KingFisher systems, the reagents of choice are Applied Biosystems MagMAX kits. For example, MagMAX Viral/Pathogen Nucleic Acid Isolation Kits can be used to extract and purify RNA from swabs or other samples types. Other popular MagMAX kits help you extract genomic DNA (gDNA) from a variety of samples; circulating cell-free DNA for liquid biopsies; DNA and RNA from formalin-fixed, paraffin embedded (FFPE) samples for clinical cancer research; and total RNA and miRNA for gene expression research.
Dynabeads and SMART Digest reagents for other targets. KingFisher instruments can use Invitrogen Dynabeads magnetic beads or Thermo Scientific SMART Digest kits to capture and isolate other nucleic acids, proteins, and cell structures. For example, you could use a SMART Digest kit to automate protein digestion of a monoclonal antibody like ipilimumab or rituximab (Rituxan®) for in-depth peptide mapping and characterization. You can pair a KingFisher instrument with Dynabeads magnetic beads to capture CD9+ tumor-derived exosomes for downstream analysis with flow cytometry or western blot.
All kits and many reagents include modifiable protocols optimized for KingFisher instruments. To find kits and reagents for your application, browse the Kits, Reagents, and Protocols tab or use our Selection Guide. If you need assistance customizing reagents or developing protocols for your particular application needs, our Field Application Specialists and Technical Sales Specialists will be happy to help.
To help ensure that KingFisher systems can adapt to your changing research needs, Thermo Scientific BindIt BindIx software is included free with all KingFisher instruments.
The software lets you create, modify, and store your own protocols on your PC, transfer them to your KingFisher instrument, and track their execution on the instrument screen during the course of your run. It also allows you to define and edit steps and parameters for every part of your protocol—bind, wash, and elute—as well as define KingFisher plates and reagents in the plate layout. If you have already developed a manual protocol, you can convert to an automated protocol in minutes!
Protocols are available for MagMAX and Dynabeads nucleic acid isolation kits, as well as Dynabeads and SMART Digest protein purification products. Once loaded onto your instrument, you can modify the protocols and store them for future reuse.
Specifications |
|
Instrument size | Compact benchtop |
Throughput level | Low to medium |
Processing volume range | 50–1,000 µL: 12-pin magnet head 200–5,000 µL: 6-pin magnet head |
Sample per run | 6-12 |
Software | Bindit |
Customizable protocols | Yes (with BindIt software) |
Heating/cooling | 10ºC–75ºC (plate row block A) 4ºC–75ºC (elution strip block) |
Ultraviolet lamp | 8 watts (up to 16 hr) |
Bar code reader | With BindIt software or standalone |
Use-selectable magnetic heads | 2 |
Standalone use | Yes |
Size | 40 x 46 x 34 cm; 15.7 x 18.1 x 13.4 in. (W x D x H) |
Weight | 17 kg; 37.5 Ibs |